Products
- Main Engine And Accessories
- Host Device
- Auxiliary Machinery
- Deck Machinery
- Materials
- Life-Saving Equipment
- Fire Alarm System
- Pump
Marine Pump
Jet Pump
Plunger Pump
Centrifugal Pump
Submersible Pump
Vortex Pump
Mud Pump
Vane Pump
Lubricating Oil Pump
Gear Pump
Hydraulic Pump
Fire Pump
Mixed Flow Pump
Sludge Discharge Pump
Impurity Pump
Dredging Pump
Metering Pump
Vacuum Pump
Magnetic Pump
Process Pump
Pneumatic Pump
Multi-stage Pump
Axial Flow Pump
Other Pump
- Hydraulic Lubrication
- Valve
Globe Valve
Gate Valve
Butterfly Valve
Relief Valve
Ball Valve
Fire Control Valve
Turn The Valve
Check Valve
Valve Remote Control/Valve Co
Observation/Sight Glass
Air Pipe Head/Mud Box
Solenoid Valve
Regulator Valve
Hand Valve
Needle Valve
Quick Closing Valve Series
Plug Valve
Storm Valve
Marine Valve Group Series
Other Valve Series
- Communication Navigation
- Environmental Protection
- Marine Electrical
Transformer
Power
Distribution Board
Lamp
Explosion-Proof Electrical App
Main Auxiliary Machine Remote
Centralized Bridge Console
Engine Room Control Console
Magnetic Starter
Charging and Discharging Plate
Telegraph
Relays
Scouting INST
Fishery Detector
Anemometer
Marine Kitchen Equipment
Marine Laundry Equipment
- Marine Hardware, Tools, Bearing
- Shipbuilding Equipment
- Metal Material
Cables and Accessories
Steel Plate
Ball Flat Steel
Steel Pipe
Metal Casting/Forging
Steel Wire Rope
Copper sleeve
centrifugal casting process brass sleeve
Copper plate
Copper half bearing bush
Copper splint
Copper nut
copper friction plate
Copper flange
composite gear
copper worm wheel
Copper roller
Wedge block
High Precision Oil Groove Sleeve Con Rod Shaft Bushing
Self lubricating copper sleeve
Bronze Pipe Copper Alloy Tube
- Non-Metallic Materials
- Surface Treatment
- Welding/Cutting/Inspection
- Marine Supplies & equ
- The Whole Ship
Metering Pump--- HRP Series
- Type:Metering Pump
- CAS No:
- Qty in 20' FCL:
- Min. Order:
- Packaging:
-
Specification
Pump & Drive units
Model
HRP-54V-1, HRP-54H-1
HRP-54V-2, HRP-54H-2
Flow rate
38 mL/min
Max. discharge pressure
0.2 MPa
Stroke rate
0 to 720 spm
Tube connection bore
Ø3 X Ø6, Ø4 X Ø6, Ø1/8 X Ø1/4
Power voltage
DC12V
DC24V
Power consumption
5.6V
Current value
1.5A
1.0A
Weight
0.5kg
• This specification is based on pumping ambient clean water at rated voltage.
• Flow rate is collected at the maximum discharge pressure and 720spm. The flow rate increases as a discharge pressure decreases.
• Allowable room temperature: 0 - 40 ºC • Allowable liquid temperature: 0 - 40 ºC
• Allowable voltage deviation: ±5% of the rated voltage 12VDC: 11.4V - 12.6V, 24VDC: 22.8V - 25.2V
Control unitPulse control type
4 - 20mA control type
1 - 5V control type
Stop control type
Upper limit spm
720spm
720spm
720spm
720spm (Fixed)
Operation
One shot per signal (Synchronous operation) Note2
4-20mADC proportional operation to 0-720spm
1-5VDC proportional operation to 0-720spm
The pump stops during contact input.
Input signal
No-voltage contact or open collector Note1
Current: 4-20mADC
Voltage: 1-5VDC (Current capacity of 25mA or more)
No-voltage contact or open collector Note1
Note1: The maximum applied voltage to the contact is 12V at 5mA. When using a contact type relay, the minimum application load should be 5mA or below.
Note2: The external pulse signal is entered to run the pump over the upper limit spm, the signal is cancelled.
-
DC power voltage / vertically- or horizontally- oriented pump head
The HRP series is powered by 12VDC or 24VDC and offers an ideal fit for built-in applications. Select vertically- or horizontally-oriented pump head to get optimum mounting position in various host machines.
High resolution
Digitally-controlled spm range is 0-720spm. The minimum flow of 0.055ml per shot offers a constant imperceptible injection.
Waterproof and dustproof structure
The sealed drive unit and control unit are enclosed to a water/dust-proof rating of IP65.
• This pump is not completely water resistant. Protect the pump with a cover when installing it out of doors. Operational function
HRP pumps are controlled by an external signal and are available in the following types.
Pulse control type
A pulse signal input controls pump operation (stroke rate). The pump makes one shot per pulse synchronously.
• An input signal is required to enable operation in addition to power activation for this type.
• The pump can not exceed a maximum of 720spm, even if the external signal input instructs the pump to run beyond that speed.
4-20mA control type
The input of 4-20mA proportionally controls the pump operation (stroke rate).
• An input signal is required to enable operation in addition to power activation for this type.
1-5V control type
The input of 1-5V proportionally controls the pump operation (stroke rate).
• An input signal is required to enable operation in addition to power activation for this type.
Stop control type
The input of the stop signal suspends the pump operation.
• The type of pump starts to run at 720spm upon power activation.