Products
- Main Engine And Accessories
- Host Device
- Auxiliary Machinery
- Deck Machinery
- Materials
- Life-Saving Equipment
- Fire Alarm System
- Pump
Marine Pump
Jet Pump
Plunger Pump
Centrifugal Pump
Submersible Pump
Vortex Pump
Mud Pump
Vane Pump
Lubricating Oil Pump
Gear Pump
Hydraulic Pump
Fire Pump
Mixed Flow Pump
Sludge Discharge Pump
Impurity Pump
Dredging Pump
Metering Pump
Vacuum Pump
Magnetic Pump
Process Pump
Pneumatic Pump
Multi-stage Pump
Axial Flow Pump
Other Pump
- Hydraulic Lubrication
- Valve
Globe Valve
Gate Valve
Butterfly Valve
Relief Valve
Ball Valve
Fire Control Valve
Turn The Valve
Check Valve
Valve Remote Control/Valve Co
Observation/Sight Glass
Air Pipe Head/Mud Box
Solenoid Valve
Regulator Valve
Hand Valve
Needle Valve
Quick Closing Valve Series
Plug Valve
Storm Valve
Marine Valve Group Series
Other Valve Series
- Communication Navigation
- Environmental Protection
- Marine Electrical
Transformer
Power
Distribution Board
Lamp
Explosion-Proof Electrical App
Main Auxiliary Machine Remote
Centralized Bridge Console
Engine Room Control Console
Magnetic Starter
Charging and Discharging Plate
Telegraph
Relays
Scouting INST
Fishery Detector
Anemometer
Marine Kitchen Equipment
Marine Laundry Equipment
- Marine Hardware, Tools, Bearing
- Shipbuilding Equipment
- Metal Material
Cables and Accessories
Steel Plate
Ball Flat Steel
Steel Pipe
Metal Casting/Forging
Steel Wire Rope
Copper sleeve
centrifugal casting process brass sleeve
Copper plate
Copper half bearing bush
Copper splint
Copper nut
copper friction plate
Copper flange
composite gear
copper worm wheel
Copper roller
Wedge block
High Precision Oil Groove Sleeve Con Rod Shaft Bushing
Self lubricating copper sleeve
Bronze Pipe Copper Alloy Tube
- Non-Metallic Materials
- Surface Treatment
- Welding/Cutting/Inspection
- Marine Supplies & equ
- The Whole Ship
Mixed gas(IG-541) fire extinguishing system
- Type:Fire-Fighting Eqpt
- CAS No:
- Qty in 20' FCL:
- Min. Order:
- Packaging:
-
1.Safety discharge device
2.Drive gas line one-way valve
3.Drive device (electromagnetic type)
4.Container valve (drive gas)
5.Drive gas bottle group
6.Extinguishing agent bottle group
7.Container valve (Fire extinguishing agent)
8.Pneumatic manual starter
9.Low leakage high sealing valve
10.Pressure gauge
11.Signal feedback device
12.Collecting pipe
13.Connecting pipe
14.Extinguisher circulation line one-way valve
15.Bottle holder
16.Nozzle
17.Emergency Start/Stop Button
18.Gas release door light
19.Sound and light alarm
20.Heat detector
21.Smoke detector
1.Low leakage high sealing valve (Drive gas)
2.Pressure gauge
3.Container valve (Fire extinguishing agent)
4.Extinguishing agent bottle group
5.Drive gas bottle group
6.Container valve (drive gas)
7.Drive device (electromagnetic type)
8.Drive gas line one-way valve
9.Select valve
10.Signal feedback device
11.Collecting pipe
12.Pneumatic manual starter
13.Connecting pipe
14.Extinguisher circulation line one-way valve
15.Bottle holder
16.Nozzle
17.Safety discharge device
18.Emergency Start/Stop Button
19.Gas release door light
20.Sound and light alarm
21.Heat detector
22.Smoke detector
System implementation standards
GA400-2002
"Gas Extinguishing Systems and Components Performance Requirements and Test Methods"Ambient temperature (℃)
0~50
Pressure
Storage pressure (at 21°C) MPa
15.0
Maximum working pressure (at 50°C) MPa
17.2
Minimum working pressure (0°C) MPa
13.6
Storage container filling pressure (at 20°C) MPa
15.0±0.2
System injection time (s)
≤60s
Delay time(s)
0~30
Pipeline system maximum working pressure (MPa)
7
Extinguishing agent bottle volume (L)
80
Fire extinguishing agent filling rate (15MPa)
211.15Kg/m³
Steel bottle external diameter
(mm)¢279
Steel bottle height
(mm)1640
Extinguishing agent filling capacity (latm, 20°C) Kg
17
System operating voltage
AC220V 50Hz and DC24 V±15%
Starting power supply
DC24 V 1.2A
Drive gas bottle filling pressure (at 20°C) MPa
6+0.3
Start gas medium
Nitrogen (N2)
Protection area/volume
≤800m2/3600m3
System startup mode
Electric automatic, electric manual, Pneumatic manual start, mechanical emergency operation
Maximum flow from
Convert by the ratio of the volume of the pipe network to the total volume of the system bottle group which is less than 66%
-
Product features:
Extinguishing agent: Does not destroy the ozone layer, it is completely composed of natural gas in the atmosphere — Nitrogen (N2), Argon (Ar), Carbon Dioxide (CO2)
Safe to people, fire-fighting without dense fog
For environmental safety: Ozone depletion potential (ODP = 0), Global warming potential (GWP = 0)
Fire extinguishing agent long transport distance
Applicable object:
Surface fire of wood and fiber materials
Fire caused by the combustion of gasoline, heptane
Gas fire that can be cut off before fire extinguishing
Electrical equipment fire
System composition:
The system is mainly composed of fire extinguishing agent bottle group (including container valve, pressure gauge), pneumatic manual starter, selection valve, one-way valve, safety valve, low leakage high sealing valve, pressure reducing device, signal feedback device, Electromagnetic drive device, driving gas bottle group (including container valve, pressure gauge), nozzle, bottle holder, pipe system and automatic alarm fire control system and other components. According to the project requirements, the use of the above-mentioned equipment can easily form a unit-independent system and a combined distribution system to implement fire protection for single or multiple districts.
Working principle:
Total flooding system
During the specified period of time, a certain concentration of mixed gas is sprayed into the protected area, and it is evenly filled in the protected area. IG541 gas fire extinguishing equipment uses total flooding way to extinguish the fire.Unit independent system
Fire extinguishing system with fire extinguishing agent storage device, is for only one protection zone. It is the simplification of the combined distribution system. Apart from the use of a selector valve, the rest of the system is the same as the combined distribution system.