News
SM5Ei Fire Audible And Visual Alarm Parameters
Product Name: SM5Ei Fire Audible And Visual Alarm
Product Features:
At the same time, sound and light alarm signals are issued.
Unique rotating structure, easy to install and use.
With address code.
-
Technical standard
Meet the requirements of GB 26851-2005
Operating Voltage
DC18V~26V
Monitor current
T+ 、T- ≤350uA; DC24V ≤410uA
Alarm current
T+ 、T- ≤1.5mA; DC24V ≤50mA
Sound level
75dB~85dB
Line system
Two alarm buses T+, T- (with polarity)
Two power bus 24V, GND (with polarity)Installation method
Exposed wall mounting
Operating temperature
-10℃~+55℃
Relative humidity
≤95%
Dimensions
88mm×41mm×88mm(L×W×H)
Weight
About 92g